Solar Hybrid UPS 3000VA
-
Harga:Call
Deskripsi
PASCAL SOLAR HYBRID UPS 3000VA
This is a pure sine wave stand-alone inverter/charger system combining the
function of inverter, solar charger and AC charger, and provides a long
run-time uninterruptible power supply. Its comprehensive LCD display
provides system status, and user-friendly panel eases parameters settings.
Key Features :
- High-frequency switching technology for compact size and light weight
- Pure sine wave output for wide range of applications and harsh environment
- Build-in solar charger controller with MPPT technology to optimize the power utilization
- High efficient DC-to-AC conversion minimizing energy loss
- Standby Charging Mode enables battery charging even when the unit is switched off
- Intelligent cooling fan control
- Input/output isolated design for the maximum operation safety
- LCD displays comprehensive operation status
- Configurable AC input voltage range and priority for AC input or PV input
- Supports Home Appliances / Office Equipment/ Lighting Equipment/ Motor-based Equipment (such as Fan, Air-Conditioner, Washing Machines)
- Thorough protections: Input low voltage / Overload / Short circuit / Low battery alarm / Input over voltage / Over temperature
- Supports both rack and wall-mounting set-up for flexible installation
SPECIFICATION :
MODEL MAX 3000
CAPACITY 2.4KW/3000VA
INPUT
Input Voltage Waveform Pure sine wave (utility or generator)
Nominal Input Voltage 230Vac
Input voltage range 170Vac-280Vac(Normal);
90Vac-280Vac(Generator/Wide)
Max AC Input Voltage 300Vac RMS
Nominal Input Frequency 50Hz / 60Hz (Auto detection)
OUTPUT
Wave from Pure sine wave (Inverter mode)
Voltage Regulation (Inverter
Mode) ±10% RMS
Output Frequency 50Hz / 60Hz ± 1Hz
Nominal Efficiency 90% (@Inverter mode with normal DC Input; >60% R load);
95% (@Line mode with Rated R load, battery full charged)
Capable of starting electric motor 1.5HP
Power Factor 0.8
Over-Load Protection Tripped off after 5s@≥150% load
Tripped off after 10s@110%~150% load
Transfer Time
(AC to DC)
Normal range : 10ms (typical) 15ms (max)
Generator/wide range: 20ms (typical) 40ms (max)
Power Limitation
BATTERY
Battery Voltage 24.0Vdc ± 0.6Vdc
Battery low alarm voltage 21.0Vdc ± 0.6Vdc
Battery low shut-down voltage 20.0Vdc ± 0.6Vdc
AC CHARGER
Charger Current 10A @Vi/p<170Vac or Vi/p>280Vac; 20A@Vi/p=230Vac
Boost charger voltage (bat. Type) 28.4Vdc
Floating charger voltage (bat.
Type) 27.4Vdc
Over charger Voltage 30.0Vdc
SOLAR CHARGER MODULE
Max Charger current 40A
Charger Power 800W
System DC Voltage 24.0Vdc
Operating Voltage Range 30~75Vdc
PV Optimal Work Voltage Range 45~72Vdc
Max. PV Array Open Circuit 75Vdc
Voltage
MAX. PV Input Current 20A
AUDIBLE ALARM
Low Battery at Inverter Mode Beeps 1 time every 2s
Overload 110%~150%load: beep 10 times every 0.5s;
>150% load: beep 5times every 0.5s then fault.
Fault Beeps continuously
PHYSICAL
Dimension(D*W*H)mm 318mm*268.4mm*85.2mm
Net weight 5.7KG